Product details

Management number 230993594 Release Date 2026/06/18 List Price $29.62 Model Number 230993594
Category

<p>1. Using high-quality materials, the quality is guaranteed</p><p>2. High precision</p><p>3. The terminals are large and easy to connect</p><p>4. Stable performance</p><p>5. With shell protection</p>

  • JY-S60 Weight Sensor Transmitter Manual
  • Technical parameter
  • .Working voltage: 24VDC
  • Output signal: 0-5V, 0-10V, 4-20mA
  • .Input sensor sensitivity: 1.0mV/V, 2.0mV/V
  • Operating temperature range: -20-80
  • .Working environment humidity: 10%RH-90%RH (no condensation)
  • Accuracy: better than 0.2%F.S
  • Gear selection
  • When DIP switch No. 1 is turned OFF, VO outputs 0-5V, when No. 1 is turned ON, VO outputs 0-10V, and when both DIP switches 1 and 2 are turned OFF, VO outputs 0-5V, IO Output 4-20mA. The other wire for current and voltage output and the negative pole of the power supply are both GND. If the zero point cannot be adjusted, you can try to turn the DIP switch 2 to ON
  • Zero adjustment
  • 1: Voltage adjustment Connect the sensor, first make the system in no-load state, adjust the voltage zero potentiometer (Vzero) to adjust the zero point. Use a multimeter to measure the voltage at the output terminal VO, and make the displayed value as close as possible to the zero point.
  • 2: Current adjustment Connect the sensor, first make the system in the no-load state, adjust the current zero potentiometer (Izero), measure the output current IO with a multimeter current block, and try to keep it as close to 4mA as possible. .
  • Product parameters:
  • Item model number: JY-S85
  • Input signal: full bridge strain sensor (weighing force tension pressure sensor)
  • Power supply voltage: DC18-26V
  • Input sensitivity: 1-3mV/V
  • Sensor excitation voltage: 5-10mV/V adjustable
  • Output signal voltage and current: DC0-5VOR0-10V/4-20mA
  • Shipping list:
  • Load Cell X1
  • current load cell load, Sensors, Active Components, Electronic Components & Supplies
Brand Dag
Weight 28.24 oz
Has written warranty No
Retail packaging S85 DC18-26V

Correction of product information

If you notice any omissions or errors in the product information on this page, please use the correction request form below.

Correction Request Form

Product Review

You must be logged in to post a review